Minimum Specifications

Minimum specifications

Elbit Filmed Green Phosphor Image Tube
TEST MINIMUM MAXIMUM
Center Resolution (lp/mm) 64
FOM 1344
Signal to Noise 21
Spots PASS

 

 

L3 Filmed MX-11769 White 1601 Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 17.0
Center Resolution 57
Halo 1.50
L3 Filmed MX-11769 White 1601 Image Tube

Spot Size

(Inches)

Zone 1 Zone 2 Zone 3
Limit Limit Limit
>.012 0 0 0
>.009-.012 0 0 2
>.006-.009 0 1 2
>.003-.006 1 2 3
Bright Spots 0 0 0
Dark spots </= .003” are acceptable

 

 

L3 Unfilmed MX-11769 White 18UM Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 24
Center Resolution 64
Figure of Merit (FOM) 1536
L3 Unfilmed MX-11769 White 18UM Image Tube

Spot Size

(Inches)

Zone 1 Zone 2 Zone 3
Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 1 1
>.003-.006 0 2 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable

 

 

L3 Unfilmed MX-11769 White 20UA Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise 28
Center Resolution 64
Figure of Merit (FOM) 1792
L3 Unfilmed MX-11769 White 20UA Image Tube

Spot Size

(Inches)

Zone 1 Zone 2 Zone 3
Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 0 1
>.003-.006 0 0 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable

 

 

L3 Unfilmed MX-11769 White 20UM Image Tube
TEST MINIMUM MAXIMUM
Signal to Noise
Center Resolution 64
Figure of Merit (FOM) 1792

 

L3 Unfilmed MX-11769 White 20UM Image Tube

Spot Size

(Inches)

Zone 1 Zone 2 Zone 3
Limit Limit Limit
>.012 0 0 0
>.009 0 0 0
>.006-.009 0 1 1
>.003-.006 0 2 2
Bright Spots 0 0 0
Dark spots </= .003” are acceptable